Plotuw8
496eef0ddce8bbfd5fef945a01c79b2c29e974ee205f9e4cfd05b821e0413e5c
README
Plotuw8 v.1.2c
==============
Shareware proposed by Guillaume Dupont
CompuServe ID 100740,1033
email: 100740.1033@compuserve.com
Key words: S3A S3C PLOT PLOTTER GRAPHICS STOCKS FINANCE HEALTH WEIGHT DIET
Introduction.
=============
Track the price of your favourite stocks, compare their variations to
an index, plot your weight, a temperature,... Plotuw8 is a simple and
easy to use plotting application: record a variable every day, every
week, or on any day you fancy, and Plotuw8 will instantly update a
graph, automatically adjusting axis and scales to display all records.
Plotuw8 allows to display up to 5 different graphs on the same screen,
to zoom in on a particular time zone, or to delete records between two
dates... One can instantly create a new graph, import data from a text
file like the ones produced by ReadCis, and update a whole set of
graphs at once, or bring data from another application (e.g. spreadsheet).
Content.
========
The plotuw8.zip file contains the following:
- readme.txt is this documentation
- plotuw8.opa is the application file
- plotuw8.rsc is a help file
- sample.plo is an example
- changes.txt summarizes the main changes from previous version.
Installation.
=============
To install Plotuw8:
- copy plotuw8.opa to any \app\ directory
- copy plotuw8.rsc and sample.plo to the \opd\ directory on the
internal disk.
- install the application like any other Psion application, by
pressing <Psion-I> in the system screen...
To install version 1.2c if you had installed a previous version:
- replace plotuw8.opa and plotuw8.rsc with the newly supplied files
- remove the plotuw8 application from the system screen
- install it again.
The graphs (.plo files) created with the previous versions are
compatible with v.1.2c.
Operation.
==========
Plotuw8 can be started like any other standard Psion application:
- to use an existing graph, highlight its name under the Plotuw8
icon and press <Enter>
- to create a new graph press <PsionðN> while the cursor is under
the Plotuw8 icon.
- to delete a graph, exit the Plotuw8 programme by pressing <Psion-X>,
highlight the name of the file under the Plotuw8 icon in the system
screen, and press <Psion-D>. Then confirm with <Y>.
Press <Help> for help, or any other key to open the menu. The
different commands are:
- <Psion-R> to create one or more new records in the currently
displayed graph: key in the value and the date in the dialog window.
Then press <Tab> (to enter new records) or <Enter> (after the last
record).
- <Psion-U> to spot and update, or delete, one particular record. A
grey square appears at the centre of the screen (adjust contrast
with Psion-> or Psion-< if necessary). Move it with arrows (plus
<Ctrl> or <Psion> for speed) until you place the target point
exactly at its centre, and press <Enter>. If you have not missed
the point, a window will open. You can then update the record (and
press the key <U>) or delete it (press <D>).
- <Psion-D> to delete all records between 2 dates. The selection
process is the same as for "Zoom" (see Psion-Z under).
- <Psion-P> to display all records as percentage of the value at one
reference date. Useful to assess the relative variations of a
variable, or to compare the relative evolution of two or more
variables. Do the following:
* open the graph corresponding to one variable,
* press <Psion-A> (see after) to display a second variable on
the same screen,
* press <Psion-P>,
* select the date at which both variable will be 100%,
* press <Enter> to see the modified graph.
- <Psion-Z> to zoom in on a particular zone: a vertical grey line
appears at the centre of the screen (adjust contrast if necessary).
The selection process is the same as in standard Psion applications:
move the line with the left and right arrows (plus <Ctrl> for speed,
or <Psion> to reach the screen border), then anchor the line by
pressing <Shift> and open a grey selection window by pressing one
arrow (plus <Ctrl> or <Psion> for speed), while <Shift> is kept
pressed. A special information window in the upper left part of the
screen shows the limit dates of the selection. Press <Enter> to
confirm the selection.
Press <Esc> or <Psion-Z> to exit the zoom mode, or any other key
to open a menu.
- <Psion-V> to open a window, where records are displayed (date and
value, 8 at a time). Use Up/Down arrows, PgUp/PgDn or Ctrl-PgUp/
PgDn to move in the window, or Right/Left arrows to move the window
itself. <Esc> to close it.
- <Psion-A> to display another graph on the same screen. Up to 5
graphs can be displayed simultaneously on one screen. Press <Tab>
to display a legend.
- <Psion-O> to open an existing graph
- <Psion-N> to create a new graph. Use any valid Psion file name (8
characters max,...).
- <Psion-M> to merge another graph into the displayed graph: the
points of the second graph become part of the displayed graph,
permanently. The merged graph file is kept intact.
- <Psion-I> to import data from a text file. Three options are now
available:
"Several existing files, one date":
a typical example is importing the quotes of a set of shares,
downloaded at one date into a text file, like quotes.cis obtained
with ReadCis. Plotuw8 works from a "Labels" table, where a label
or "ticker" corresponds to each name of graph (see <Psion-L>
under). The programme will look for one share in each line of text,
looking first for the label, then for the value, in the columns
specified by the user. In the case of quotes.cis the labels are
found in column 1, and the last quotes in column 5. The file looks
like this (the first 2 lines, which contain no matching labels are
ignored by the programme):
<<
Ticker Volume High Low Last Change Cur Updated
------------ ------ -------- ------- -------- ------ --- ----------
AIRP.PA 715 797.000 786.000 792.000 +2.000 FRF 5:00 CET
ACCP.PA 616 633.000 623.000 626.000 -3.000 FRF 5:00 CET
AXAF.PA 2684 314.800 310.700 313.200 +1.600 FRF 5:00 CET
CCFP.PA 1034 233.600 231.100 232.900 +1.400 FRF 4:59 CET
EUTL.PA 36437 7.900 7.700 7.800 +0.100 FRF 5:00 CET
LAFP.PA 2786 305.900 300.000 302.800 -0.800 FRF 5:00 CET
TOTF.PA 3369 408.000 401.500 405.500 -0.500 FRF 5:00 CET
TFFP.PA 92 573.000 560.000 569.000 +5.000 FRF 5:00 CET
CGEP.PA 2676 451.400 444.200 446.500 -5.000 FRF 5:00 CET
MWDP.PA 55 465.000 459.000 465.000 +5.000 FRF 4:59 CET
Issue:
>>
The user must answer several questions, before the import starts:
* name of the import text file
* date of the records
* number of the column where the labels, or tickers will be
found (column 1 in this case)
* number of the column where the quotes will be found (column
5 in this case)
* type of separators ("spaces and tabulations" in this case).
When the name of the import file has been selected, its first few
lines are displayed in a background window, where the user can
check the structure, count the columns,...
"New graph, several dates" or "One existing graph, several dates":
In this case, once the import text file has been chosen, and a
graph name has been selected or created, Plotuw8 will look for one
record per line of text. The format for entries is:
xxx dd*mm*yy xxx data
or
xxx dd*mm*yyyy xxx data
where dd*mm*yy or dd*mm*yyyy is the date, xxx and * can be any non
numerical set of characters, and data is the value (separators are
interpreted according to the system settings).
The following is a valid example of a text file for import, which
will produce a graph with 5 points (assuming that the system
decimal point is "Dot"):
le 24.5.94 33.2
le 12.6.1994 ++++ 35.6
15/7/94 anytext 38.6
anything 20**08**94 37
25-8-1994 35
- <Psion-B> to bring data from another application and create a new
graph. Any text, which has been highlighted in another application
supporting Link Paste (word, data, spreadsheet,...) will be brought
in and interpreted in the same way as in the "import" option (see
above).
- <Psion-L> to edit the "Labels" table for import labels (see above).
The table is displayed on the right side of the screen, and a series
of command buttons on the left side. Note that there can be several
labels for one graph name, but only one graph for one label...
- Press <Help> for the help menu.
Files / disk space management.
==============================
The plotuw8.opa file can be located on any disk, in an \app\ directory.
On the first time the programme is run after installation, it creates
an \opd\plotuw8\ subdirectory on the internal disk (m:). A plotuw8.cfg
file is created and stored in the m:\opd\plotuw8\ directory. This
file must remain in that directory on the internal disk.
At the first run all the .plo graph files found in the internal disk's
\opd\ directory are also moved to the m:\opd\plotuw8\ directory. The
user is then free to create other \opd\plotuw8\ on another disks (if
not flash disks!), and create new graph files, or move existing ones
there.
At the first run the help file plotw8.rsc, if found in the \opd\
directory on the internal disk, is moved to the m:\opd\plotuw8\
directory. The user can move it to any other \opd\plotuw8\ directory
on any disk.
As the registration process has been changed, the previously supplied
plotuw8.reg file is of no more use in this version. It can be deleted.
Registration.
=============
Plotuw8 is Shareware. You can use it freely during 14 days. After
this period, if you find it useful, please register. Otherwise
remove it from your computer. Registration fee is US$15.00.
You can register via SWREG (GO SWREG. Registration ID: 10551).
Alternatively you can send US$15, £10, DM20, CHF20, or FF70 in cash
by mail. Send bank notes, no checks please. Do not forget to send
your e-mail address with payment. Note that sending cash by mail is at
sender's risk. My address is:
Guillaume Dupont
25, rue Pauline Borghese
92200 Neuilly sur Seine
France
Upgrade from previous versions is free.
Non registered version allows to plot 12 points only on each graph
(although an indefinite number can be recorded). Registered users will
receive via e-mail a registration code which allows to plot full
graphs. This code must be entered in the registration window (<Psion-W>,
then <R>) exactly as mailed (spaces, upper cases...).
Disclaimer of responsibility.
=============================
Users of Plotuw8 must accept this disclaimer of warranty: "Plotuw8
is supplied as is. The author disclaims all warranties, expressed or
implied, including, without limitation, warranties of fitness for
any purpose. The author assumes no liability for damages, direct or
consequential, which may result from the use of Plotuw8 or any of its
accompanying files".
Last update 1 Feb 1997.
-=-
Unknown
Plotuw8
NWT_Psion3.tar
→
NWT_Psion3/apps/finance/porfolio.zip
→
PLOTUW.ZIP
→
PLOTUW8.OPA
496eef0ddce8bbfd5fef945a01c79b2c29e974ee205f9e4cfd05b821e0413e5c
|
|
Plotuw8
NWT_Psion3.tar
→
NWT_Psion3/apps/draw/plotuw12.zip
→
PLOTUW8.OPA
496eef0ddce8bbfd5fef945a01c79b2c29e974ee205f9e4cfd05b821e0413e5c
|